Transit mode – H3C Technologies H3C S10500 Series Switches User Manual
Page 22
![background image](https://www.manualsdir.com/files/812733/content/doc022.png)
11
Transit mode
FCoE supports FC SANs built on lossless Ethernet networks, and allows Transit switches to be added
between FCF switches and ENodes.
shows a scenario where ENodes are connected to FCF
switches through a Transit switch.
Figure 12 Transit network diagram
Ethernet interfaces on a Transit switch can operate in ENode mode or FCF mode.
•
An Ethernet interface connected to an ENode must be configured to operate in ENode mode.
•
An Ethernet interface connected to an FCF switch must be configured to operate in FCF mode.
When Transit switches are interconnected, you must configure Ethernet interfaces to operate in the
correct modes. As shown in
, ENode 2 can register with only FCF switch 2. To register ENode
2 with FCF switch 1, you must swap the operating modes of the Ethernet interfaces that connect the two
Transit switches.
Figure 13 Transit cascading network diagram
shows a network scenario where both Transit and NPV switches are present.