Configuring link monitoring, Configuring errored frame event detection, Configuring errored frame period event detection – H3C Technologies H3C S12500 Series Switches User Manual
Page 25: Configuring errored frame seconds event detection

14
Configuring link monitoring
CAUTION:
Make sure the errored frame seconds triggering threshold is less than the errored frame seconds detection
interval. Otherwise, no errored frame seconds event can be generated.
Configuring errored frame event detection
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the errored frame
event detection interval.
oam errored-frame period
period-value
Optional.
1 second by default.
3.
Configure the errored frame
event triggering threshold.
oam errored-frame threshold
threshold-value
Optional.
1 by default.
Configuring errored frame period event detection
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the errored frame
period event detection period.
oam errored-frame-period period
period-value
Optional.
1000 milliseconds by default.
3.
Configure the errored frame
period event triggering
threshold.
oam errored-frame-period
threshold threshold-value
Optional.
1 by default.
Configuring errored frame seconds event detection
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the errored frame
seconds event detection
interval.
oam errored-frame-seconds
period period-value
Optional.
60 second by default.
3.
Configure the errored frame
seconds event triggering
threshold.
oam errored-frame-seconds
threshold threshold-value
Optional.
1 by default.
NOTE:
After Ethernet OAM connections are established, the link monitoring periods and thresholds configured in
this section take effect on all Ethernet ports automatically.