H3C Technologies H3C S12500 Series Switches User Manual
Page 239

228
Virtual IP : 10.1.1.10
Master IP : 10.1.1.2
VRRP Track Information:
Track Object : 1 State : Negative Pri Reduced : 30
# After shutting down the uplink interface on Switch A, display detailed information about VRRP
group 1 on Switch B.
[SwitchB-Vlan-interface2] display vrrp verbose
IPv4 Standby Information:
Run Mode : Standard
Run Method : Virtual MAC
Total number of virtual routers : 1
Interface Vlan-interface2
VRID : 1 Adver Timer : 1
Admin Status : Up State : Master
Config Pri : 100 Running Pri : 100
Preempt Mode : Yes Delay Time : 0
Auth Type : None
Virtual IP : 10.1.1.10
Virtual MAC : 0000-5e00-0101
Master IP : 10.1.1.2
The output shows that when the uplink interface on Switch A is shut down, the priority of Switch A
decreases to 80. Switch A becomes the backup, and Switch B becomes the master. Packets from
Host A to Host B are forwarded through Switch B.