119

Device ID: 000f-e23d-5af0

Preemption mode: ROLE

Preemption delay: 1(s)

Control VLAN: 10

Protected VLAN: Reference Instance 1

Member Role State Flush-count Last-flush-time

-----------------------------------------------------------------------------

GigabitEthernet4/0/1 MASTER ACTVIE 5 16:37:20 2010/02/21

GigabitEthernet4/0/2 SLAVE STANDBY 1 17:45:20 2010/02/21

Smart link group 2 information:

Device ID: 000f-e23d-5af0

Preemption mode: ROLE

Preemption delay: 1(s)

Control VLAN: 110

Protected VLAN: Reference Instance 2

Member Role State Flush-count Last-flush-time

-----------------------------------------------------------------------------

GigabitEthernet4/0/2 MASTER ACTVIE 5 16:37:20 2010/02/21

GigabitEthernet4/0/1 SLAVE STANDBY 1 17:45:20 2010/02/21

You can use the display smart-link flush command to display the flush messages received on a

switch.
# Display the flush messages received on Switch B.

display smart-link flush

Received flush packets : 5

Receiving interface of the last flush packet : GigabitEthernet4/0/2

Receiving time of the last flush packet : 16:25:21 2010/02/21

Device ID of the last flush packet : 000f-e23d-5af0

Control VLAN of the last flush packet : 10