H3C Technologies H3C S12500 Series Switches User Manual
Page 130

119
Device ID: 000f-e23d-5af0
Preemption mode: ROLE
Preemption delay: 1(s)
Control VLAN: 10
Protected VLAN: Reference Instance 1
Member Role State Flush-count Last-flush-time
-----------------------------------------------------------------------------
GigabitEthernet4/0/1 MASTER ACTVIE 5 16:37:20 2010/02/21
GigabitEthernet4/0/2 SLAVE STANDBY 1 17:45:20 2010/02/21
Smart link group 2 information:
Device ID: 000f-e23d-5af0
Preemption mode: ROLE
Preemption delay: 1(s)
Control VLAN: 110
Protected VLAN: Reference Instance 2
Member Role State Flush-count Last-flush-time
-----------------------------------------------------------------------------
GigabitEthernet4/0/2 MASTER ACTVIE 5 16:37:20 2010/02/21
GigabitEthernet4/0/1 SLAVE STANDBY 1 17:45:20 2010/02/21
You can use the display smart-link flush command to display the flush messages received on a
switch.
# Display the flush messages received on Switch B.
Received flush packets : 5
Receiving interface of the last flush packet : GigabitEthernet4/0/2
Receiving time of the last flush packet : 16:25:21 2010/02/21
Device ID of the last flush packet : 000f-e23d-5af0
Control VLAN of the last flush packet : 10