CnF. 3CnF. 3CnF. 3CnF. 3CnF. 3

46

AFtr

= The functions listed at Note (**) are calculated

after

after

after

after

after to apply the action selected by “ñC.Cn”
(“Main control output conditioning” [C.F06])
parameter.

Note (**)

Note (**)

Note (**)

Note (**)

Note (**)
- "Main control output limiters" - for more details see [r.E04] and

[r.E05] parameters.

- "Main control output max rate of rise" (see [r.E06]).
- "Control output display value" - for more details see "Display

function" paragraph at pag. 62 and [C.F07], [C.F08], [C.F09]
and [C.F10] parameters.

- "Threshold for alarm on control output value" - for more details

see [r.F01], [r.F05] [r.F09] and [r.F13] parameters.

- The control output value displayed by bargraph.

- Secondary control output conditioning

- Secondary control output conditioning

- Secondary control output conditioning

- Secondary control output conditioning

- Secondary control output conditioning

- [C.F12]

- [C.F12]

- [C.F12]

- [C.F12]

- [C.F12]

This parameter will be available only when secondary control
output is configured.
Range: norñ = The control output is calculated by the PID

CñPL = The control output is complemented (100-PID

calculated value)

Ouic = The control output is conditioned to match a

“QUICK OPENING” flow characteristic

Eou

= The control output is conditioned to match an

“EQUAL PERCENTAGE” flow characteristic

For more details see also NOTE about output conditioning

NOTE about output conditioning

NOTE about output conditioning

NOTE about output conditioning

NOTE about output conditioning

at page 43.

- Secondary control output in engineer-

- Secondary control output in engineer-

- Secondary control output in engineer-

- Secondary control output in engineer-

- Secondary control output in engineer-

ing unit - [C.F13]

ing unit - [C.F13]

ing unit - [C.F13]

ing unit - [C.F13]

ing unit - [C.F13]

This parameter will be available only when secondary control
output is configured.
Range: nO

= Scalable is not required

YES

= Scalable is required

NOTE

NOTE

NOTE

NOTE

NOTE: This scaling allows to display the output value in
engineering units instead of in percent.

- Secondary control output decimal point

- Secondary control output decimal point

- Secondary control output decimal point

- Secondary control output decimal point

- Secondary control output decimal point

position - [C.F14]

position - [C.F14]

position - [C.F14]

position - [C.F14]

position - [C.F14]

This parameter will be available only when "S.SCL" ("Secondary
control output in engineering units" [C.F13]) is set to "YES".
Range:

----.

= No decimal figure

---.-

= One decimal figure.

--.--

= Two decimal figures.

mkc-ssi.pmd

06/07/2004, 12.19

46