Super Systems 20Q User Manual
Page 27
23
Security code setting
Security code setting
Security code setting
Security code setting
Security code setting:
1) Remove the instrument from its case.
2) Set the internal dip switch V101 as follows:
- V101.1 = OFF - V101.2 = ON
- V101.3 = OFF - V101.4 = OFF
3) Re-insert the instrument.
4) Switch on the instrument. The display will show:
The upper display shows that the security code setting mode
is selected while the lower display shows the firmware version.
5) Push the FUNC pushbutton.
Run time security code
Run time security code
Run time security code
Run time security code
Run time security code
The display will show:
Note
Note
Note
Note
Note: the middle display shows the current status of the run
time security code ("0", "1" or "On").
By and push-button, set "S.run" parameter as follows:
0
No protection (it is ever possible to modify all run time
parameters);
1
ever protected (it is never possible to modify a run time
parameter);
from 2 to 250 security code for run time parameter protection.
NOTES
NOTES
NOTES
NOTES
NOTES:
1) The selected value of a security code cannot be displayed anymore
and, coming back to the "S.run" parameter, the display will show
:
- "On" when "S.run" is different from 0 or 1
- "0" when "S.run" is equal to 0
- "1" when "S.run" is equal to 1.
When the security code is forgotten, a new value can be set.
2) When "S.run" is different from 0 or 1, the "run time default "
and the "run time hidden" groups are ever protected by security
code.