6.2

Terminal assignment / legend - I/0 module

Terminal assignment I/0 module 01

Designation

Input

Output

Signal

Description

Power

X

Power supply I/O 230V

PE

X

Power supply primary pump IM

S01.1

X

Solar probe collector

S02.1

X

Solar probe storage tank, bottom

S03.1

X

Solar probe inlet HM solar

S04.1

X

Solar probe RF HM solar

S05.1

X

Circulation RF temp./impulse

S06.1

X

2nd mixed heating cycle inlet probe

S07.1

X

Probe refrigerant line

S08.1

X

Domestic hot-water tank

S09.1

X

Probe storage tank with solar heating (ext. energy)

S10.1

X

External probe

S11.1

X

1st mixed heating cycle RF probe

S12.1

X

1st mixed heating cycle inlet probe

S13.1

X

Heat pump inlet

S14.1

X

2nd mixed heating cycle RF probe

S15.1

X

Heat pump RF

S16.1

X

Energy supplier contact (NC) / dew point monitoring

S20.1

X

Not connected

S21.1

X

Not connected

S22.1

X

Not connected

S23.1

X

Ultrasonic flow rate meter solar, impulse rate

S24.1

X

Ultrasonic flow rate meter HP, impulse rate

S25.1

X

HP electricity meter S0

S26.1

X

Household electricity S0

S27.1

X

Not connected

S28.1

X

PV yield electricity meter S0

S29.1

X

PV in-feed electricity meter S0

A01.1

X

Solar pump, unregulated (230V)

A02.1

X

1st mixed heating cycle pump (230V) switched

A03.1

X

Unmixed heating cycle pump (230V)

A04.1

X

Circulation pump (230V)

A10.1

X

Changeover valve, hot water preparation

REMKO Smart WP MANAGER