6.2
Terminal assignment / legend - I/0 module
Terminal assignment I/0 module 01
Designation
Input
Output
Signal
Description
Power
X
Power supply I/O 230V
PE
X
Power supply primary pump IM
S01.1
X
Solar probe collector
S02.1
X
Solar probe storage tank, bottom
S03.1
X
Solar probe inlet HM solar
S04.1
X
Solar probe RF HM solar
S05.1
X
Circulation RF temp./impulse
S06.1
X
2nd mixed heating cycle inlet probe
S07.1
X
Probe refrigerant line
S08.1
X
Domestic hot-water tank
S09.1
X
Probe storage tank with solar heating (ext. energy)
S10.1
X
External probe
S11.1
X
1st mixed heating cycle RF probe
S12.1
X
1st mixed heating cycle inlet probe
S13.1
X
Heat pump inlet
S14.1
X
2nd mixed heating cycle RF probe
S15.1
X
Heat pump RF
S16.1
X
Energy supplier contact (NC) / dew point monitoring
S20.1
X
Not connected
S21.1
X
Not connected
S22.1
X
Not connected
S23.1
X
Ultrasonic flow rate meter solar, impulse rate
S24.1
X
Ultrasonic flow rate meter HP, impulse rate
S25.1
X
HP electricity meter S0
S26.1
X
Household electricity S0
S27.1
X
Not connected
S28.1
X
PV yield electricity meter S0
S29.1
X
PV in-feed electricity meter S0
A01.1
X
Solar pump, unregulated (230V)
A02.1
X
1st mixed heating cycle pump (230V) switched
A03.1
X
Unmixed heating cycle pump (230V)
A04.1
X
Circulation pump (230V)
A10.1
X
Changeover valve, hot water preparation
REMKO Smart WP MANAGER