Domestic hot-water heating
Optionally, you can activate or deactivate the
"Domestic hot-water heating" function. Activate
Domestic hot-water heating if domestic water has
to be heated for washing or showering (select with
the rotary knob and confirm with "OK"). When this
function is activated, the associated parameters
are then queried. Pay attention to information on
the display.
Fig. 41: Domestic hot-water heating
Press "Next".
Reheating
Desired charging temperature for the hot water
storage tank.
Set temperature to which conventional reheating
should heat the storage tank to ensure comfort. If
there is a solar yield, the storage tank can become
substantially warmer. The maximum temperature
for solar charging can be modified under Settings/
Solar/Storage tank.
For efficiency reasons, the lowest possible set tem-
perature should be selected. If the available quan-
tity of hot water is insufficient, the value should be
increased. Pay attention to the maximum tempera-
ture of the heat pump.
Select the storage tank set temperature with the
rotary knob and confirm with "OK".
Fig. 42: Reheating
Menu item
Parameter
Factory setting
Storage tank
set temp.
40°C - 65°C
Factory recom-
mendation
45°C
Press "Next".
REMKO Smart WP MANAGER