"Settings" menu item output restriction

(night mode with noise optimisation)

Fig. 90: "Output restriction" menu item

Under the level "Expert/heat pump/output restric-

tion" it is possible to adjust the following parame-

ters for the output reduction and associated noise

optimisation.

Fig. 91: Time program

Fig. 92: Time window overview

Output reduction is set to active in the factory from

22:00 hrs to 06:00 hrs. This time window can be

individually adjusted for the system operator.

The time program is active for all connected cir-

cuits (HGU, HGM 1-4,HW and cooling cycle).

Fig. 93: Output restriction HTG (normal)

If a reduction is required for "normal" heating mode

(e.g. 06:00 - 22:00 hrs) then the output can be

aligned accordingly.

Fig. 94: Output restriction HTG (reduced)

The output restriction in "reduced" operation (22:00

- 06:00 hrs) is set to 60% in the factory. Adjustment

of the output must take depending on the installa-

tion site.

Fig. 95: Output restriction cooling (normal)

If a reduction is required for "normal" cooling mode

(e.g. 06:00 - 22:00 hrs) then the output can be

aligned accordingly.