All measurements in mm



GmbH

Befestigungs- und Schallschutzsysteme
Hessenstraße 11
Tel +49 6122/808-0

65719 Hofheim-Wallau

Fax +49 6122/4702

Projekt : Konsolenset mit zusätzlicher Stützstrebe

Zeichnungs-Nr.: AT09B9554-11 Blatt 1

VMA : Nahler

MPC-Schienenkonsole 38/40,

Länge: 560 mm, verzinkt,

MPC-Stützstrebe für Profile 38/40-40/120,

Länge: 440 mm, verzinkt

MPC-Systemschiene 38/40,

Länge: 520 mm, verzinkt

Alle Angaben sind am Bau zu prüfen !

Datei: AT09B9554-11.mtp

MPDesigner Version 9.5.0(c75)

TYPE WKM 560 Plus wall console

NOTE

Edition GB - W12

Use the type of fasteners appropriate for the type of wall!

Only install the wall console on the building where structurally permitted.

Make sure there are no utility lines where holes are drilled in the wall for the anchors.

The wall console must be installed so that it can support the weight of the device it is intended to carry.

1. Place both wall tracks on the wall, at the same height and at a distance from one another corresponding with the

distance between the anchor feet on the outer unit to be mounted on the console. (measurement B).

2. Mark the positions for the holes to be drilled for the wall track anchors.
3. Drill the holes, and using the anchors, screws and the steel angles provided for the purpose, secure the wall tracks

(see drawing).

4. Align the wall tracks and adjust for any unevenness in the wall so that the wall tracks hang horizontally. Tighten the

screws until the tracks sit securely.

5. Using the enclosed hammer-head screws at the top end of the wall tracks, attach the brackets (see drawing).
6. Align the brackets so that they are horizontal before being secured.
7. Attach the cross braces between the wall track and the bracket (see drawing).
8. Attach the vibration dampers on the brackets at a distance corresponding with the distance between the anchor feet

on the outer part (measurement T) to be mounted on the console as shown in the drawing. The screws can be moved
easily in the track.

9. Position the outer unit on the vibration dampers and secure it in place using the enclosed nuts.

INSTALLATION

WKM 560 Plus

Bracket

560 mm

Wall track

520 mm

Overall depth

600 mm

max. weight

200 kg

EDP no.

260078

Cross brace 45°

Bracket


Wall track

40

600

520

560

Item Description

Quantity

1

Wall track

2

2

Bracket

2

3

Vibration dampers with

nuts

4

4

Steel angle

4

5

Hammer-head screws

4

6

Cross brace 45°

2

Scope of delivery

Technical data