Page 46

Medium flow rate probe
The amount of heat delivered from solar yields is
recorded continuously, and can be called up in the
form of a daily or cumulative value.
If no medium flow rate probe is installed, a manual
medium flow rate can be selected. The heat meter
can also be deactivated, if desired.
Fig. 82: Selecting the medium flow rate probe
Menu item
Parameter
Factory setting
Solar HM
Deactivated
Setting with
heat meter
installed
Manual medium
flow rate
Medium flow
rate probe
Press "Next".
Setting the impulse rate of the solar medium
flow rate probe
The impulse rate may only be changed (select with
the rotary knob and confirm with "OK") if the loss in
pressure from the collector arrays and the line is
too great.
Recommendation: adjust the medium flow rate to
suit the hydraulic system provided by the customer
Fig. 83: Medium flow rate probe - setting the
impulse rate
Menu item
Parameter
Factory setting
Impulse rate
for medium
flow
rate
(if activated)
0 - 10 ml / Imp
5.7 ml / Imp
Press "Next".
Manual medium flow rate
If there is no medium flow rate probe in the solar
station, manual medium flow rate must be selected
(select with the rotary knob and confirm with "OK").
The heat meter can also be deactivated, if desired.
Press "Next".
Specifying the medium flow rate
The medium flow rate is specified in order to calcu-
late the amount of solar heat. The value can be
viewed on the flow meter when the solar pump is
running.
Enter the value (select with the rotary knob and
confirm with "OK").
Press "Next".
REMKO Smart WP MANAGER
46