"Settings" menu item (continued) - Expert

Authorisa-

tion level

Level 2 menu

item

Level 3 menu item

Level 4 menu item

Info

Heating /

cooling

Building adaptation

Building time constant

You can find

many of the indi-

vidual info texts

about the level

2-4 menu items

on your Smart

Control

Standard heating load

Inertia of the heating curve

Mode

Room climate mode

Differ. from cooling limit

Differ. from heating limit

Floor screed drying func-

tion

After the floor screed

function we recommend

this function manually to

finish by deactivating!

Floor screed fun. status

Start / end temperature

Max.temperature

Heating phase increment

Drying time

Time at high temp.

Incremental cooling phase

Time at low temp.

Cooling

Cooling cycle mode

Cooling curve adjustment

Time program

Setpoint increase

Room unit

Dewpoint monitoring

Cooling

Fixed value

Dew point distance

Temperature difference

Floor screed function

Designation

Value range

Factory setting

Cust. system

Floor screed func. status

Activated / Deactivated

Deactivated

Start/end/max/temp.

"10 °C-50 °C"/"20 °C-50 °C"

20 °C/35 °C

Incremental heating phase

0.0 K - 10.0 K

5.0 K

Drying time

0.0 h - 192 h

24 h

Time at high temp.

0.0 h - 192 h

96 h

Incremental cooling phase

0.0 K - 10.0 K

5.0 K

Time at low temp.

0.0 h - 192 h

24 h

71