beautypg.com

REMKO WPM-Smart-Control-Manual for specialists-WKF-120 User Manual

Page 33

background image

Hot water circulation

If there is a hot water circulation pump in the

building, which you are intending to operate in an

energy-saving manner using the controller, this

function must be activated (select with the rotary

knob and confirm with "OK").

Fig. 43: Hot water circulation

Menu item

Parameter

Factory setting

Hot

water

circulation

Deactivated

As required

Activated

Press "Next".

Circulation type

(dependent on which probes are used)

Impulse circulation:

If briefly dispensing water triggers an impulse on

the flow-operated safety device, this is registered

by the controller and the circulation pump is started

up. This means that the circulation is also active

when it is required.

Temperature-guided circulation:

Temperature-guided circulation keeps the hot

water temperature at the set temperature.

Select the circulation type with the rotary knob,

then confirm the entry with "OK".

Fig. 44: Selecting the circulation type

Menu item

Parameter

Factory setting

Circulation

type

Impulse

circulation

As required

Temperature-

guided circula-

tion

Press "Next".