"Chimney sweep" menu item - Expert

Authorisa-

tion level

Level 2 menu item

Level 3 menu item

Info

Mode

Normal operation / test mode

You can find

many of the indi-

vidual info texts

about the level

2-3 menu items

on your Smart

Control

Hot water valve

Deactivated / activated

Running time

15 - 90 minutes

Fig. 101: Level "Expert" - chimney sweep function

In order to test boilers or wall heaters with bivalent

systems it is possible to manually enable the

second heat generator in the "user and expert

level".

The test mode can be changed from "normal

mode" to "test mode". During testing it is possible

to activate the changeover valve to the hot water

tank, in order to feed the heat generated to the hot

water tank. This function is limited to 30 minutes

with the factory settings. The restriction can be set

from 15 to 90 minutes. Once the run-time has

lapsed, normal heat pump mode becomes active

automatically.

Fig. 102: "Normal operation" mode

Fig. 103: "Test mode"