beautypg.com

Read log – Measurement Computing Micro 488/EX rev.2.1 User Manual

Page 134

background image

Section 5

Command Descriptions

5.64

READ LOG

The READ LOG command is used to request a copy of the data contained within

the LOG Buffer to be sent out the serial port. The logged data is not deleted when read.
To delete the LOG Buffer, the ERASE LOG or FACTORY commands are used.

The number of characters contained within the LOG Buffer can be determined with

the LOG MEMORY command. READing the LOG buffer during macro execution will
generate a 'LOGGING ERROR'

SYNTAX

READ

LOG

RESPONSE

Data contained within the LOG Buffer.

MODE Any

BUS STATES

None

EXAMPLES

PRINT#1,"MACRO 1"

Define a macro

PRINT#1,"HELLO"
PRINT#1,"ENDM"
PRINT#1,"LOG ON"

Enable logging

PRINT#1,"DOMACRO 1"

Execute the macro
The response is logged

PRINT#1,"LOG MEMORY"
INPUT #1,L

Read the memory used

PRINT L

Printed to the screen

54

Number of bytes in buffer

PRINT#1,"READ LOG"

Read the contents

INPUT #1,L$

Read the data

PRINT L$

Printed to the screen

Micro488/EX

Revision N.N Copyright (C) 1988 IOtech

PRINT#1,"ERASE LOG"

Erase the log buffer

PRINT#1,"LOG MEMORY"
INPUT #1,L

Read the memory used

PRINT L

Printed to the screen

0

0 bytes in buffer