beautypg.com

Measurement Computing Micro 488/EX rev.2.1 User Manual

Page 12

background image

Section 1

Introduction

1.3b

EIA RS-422A:

O

Balanced voltage on TxD and RxD.

Character Set:

O

Asynchronous bit serial.

Output Voltage:

O

±5 volts minimum (RS-232C); 3.5 volts typical (RS-422A).

Input Voltage:

O

±3 volts minimum; ±15 volts maximum.

Baud Rate:

O

Selectable 110,300,600,1200,1800,2400,3600,4800,7200,9600, and 19200.

Data Format:

O

Selectable 7 or 8 data bits; 1 or 2 stop bits; odd, even, mark, space and no

parity on transmit.

Duplex:

O

Full with Echo/No Echo.

Serial Control:

O

Selectable CTS/RTS or XON/XOFF.

Terminators:

O

Selectable CR, LF, LF-CR and CR-LF.

Connector:

O

25-pin Sub-D male. RS-232C DCE configured.

Clock

Accuracy:

O

1 minute per month typical.

Battery Life:

O

10 years typical.

Information Provided:

O

Provides hours, minutes, seconds, day, month, date and year.

General

Terminal Installation Category:

O

Standard: Not Applicable.

O

CE: Category 1 for all terminals.

Dimensions:

O

188 mm deep x 140 mm wide x 68 mm high (7.39” x 5.5” x 2.68”).