beautypg.com

3 switch, Draco major 74 – IHSE USA 474 Series Draco major User Manual

Page 74

background image

Draco major

74

2011-10-11

5.3.3

Switch

You can configure the parameters for the matrix configuration in this
menu.

You have the following possibilities to access the menu:

You can select between the following settings:

Field

Selection

Description

Y (Yes)

The user can switch the video signal
from any CPU to his monitor (observer).
Keyboard/mouse control is not possible.
Note:

Switching with the key and not
.
The operator will not be informed if
further users connect as an observer to
the CPU that is connected to his
console.

Allow Sharing

N

(No)

Function not active (default)

Y

(Yes)

The User can connect to every single
CPU as an operator, even to such ones
that are related to another user. The
previous user is set to observer status.
Note:

To share K/M control Force

Connect

has to be activated.

Force
Connect

N

(No)

Function not active (default)

Y

(Yes)

Extension of 'Force Connect': If the user
connects to a CPU as an operator that
is already related to another user, the
connection to the previous user will be
completely disconnected.
Note: To share K/M control Force
Disconnect

has to be deactivated.

Force
Disconnect

N

(No)

Function not active (default)