2 fiber, Draco major 144 – IHSE USA 474 Series Draco major User Manual
Page 144

Draco major
144
2011-10-11
7.2.2
Fiber
A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as
Ethernet Hubs, Matrixes or Routers, is not allowed.
Type of Interconnect Cable (Cable notations according to VDE)
Type of cable
Specifications
Single-mode 9μm
Two fibers 9μm
I-V(ZN)H 2E9 (in-house patch cable)
I-V(ZN)HH 2E9 (in-house breakout cable)
I/AD(ZN)H 4E9 (in-house or outdoor
breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with
protection against rodents)
Multi-mode 50μm
Two fibers 50μm
I-V(ZN)H 2G50 (in-house patch cable)
I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)
Multi-mode 62.5μm
Two fibers 62.5μm
I-V(ZN)HH 2G62,5 (in-house breakout
cable)
A/DQ(ZN)B2Y
4G62,5
(outdoor cable,