Page 159: Specifications

Specifications
2011-10-11
159
8.3
Blank Screen
1
1
1
2
3
1 2
3
3
Rear View
Front View
Diagnosis
Possible Reason
Measure
Switching to a CPU Port 
without active Source 
(computer, CPU). 
Switching to a CPU Port with an
active source (computer, CPU).
Monitors 
remains dark 
after switching 
operation 
Connection of a console 
with a CON port or 
connection of a CPU to a 
CPU port not established 
correctly. 
Check connections regarding
CON and CPU ports at the 
matrix. 
LED 1 on or 
LED 2 off 
Connections CON unit, 
matrix and CPU unit. 
Check connecting cables and
connectors. (No cable, cable 
break, CPU/CON unit offline, 
CPU/CON unit connected to the 
wrong port) 
CPU unit LED 3 
green 
Connection between 
CON unit, matrix and 
CPU unit 
Establish a connection between
CON unit and CPU unit via 
matrix 
 
 