Configuration – IHSE USA 474 Series Draco major User Manual
Page 127

Configuration
2011-10-11
127
Color CPU
Port
Color CON
Port
Description
Yellow
Yellow
CPU port connected to the own console
Red
Red
CPU port connected to a different console
Red Yellwo
CPU Port connected with a different console,
video connected to the own console
Black
n.c.
CPU Port not available
By default the user is only able to switch to available CPU ports.
In the menu Configuration > System (see Chapter 5.3.3, Page 74) the
user is able to activate the options Allow Sharing, Force Connect and
Force Disconnect
.
If
Allow Sharing
is active, the user will be able to switch to an
already to another user assigned CPU by using the key
will receive the monitor display, but without the opportunity to control.
The current user will not be informed about this procedure.
If
Force Connect
is active, the user will be able to switch to any CPU
by pressing the key
including the opportunity for control. The previous user will loose his
control, but will still receive the monitor display.
If
Force Disconnect
is active, the user will be able to switch to any
CPU by pressing the key
including the opportunity for control. The previous user will be
disconnected from the CPU.