Operation – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual
Page 95
00%
00%
00%
00%
00%
00%
INLET GAS
REMOTE or LOCAL
INLET GAS
PREFLOW
SHIELD
XXX PSI/BAR
XXX PSI/BAR
XXX PSI/BAR
PLASMA
4-6
HD3070 with Automatic Gas Console
Instruction Manual
16
OPERATION
Figure 4-3
Automatic Gas Console Front Panel LCD Display
Indicates local
or remote control
system operation
Indicates plasma
inlet gas in
psi or bar
(120 psi/8.28 bar)
Indicates plasma
outlet gas pressure
Indicates location
of preflow gas
pressure and
flowrate fields
Indicates shield inlet
gas in psi or bar
(120 psi/8.28 bar)
Indicates preflow
outlet gas pressure
Indicates shield
outlet gas pressure
Indicates location
of shield gas
pressure and
flowrate fields
Indicates location
of plasma gas
pressure and
flowrate fields
Indicates PS-ERR (power
supply system error). Refer
to Power Supply System
Error List.
Indicates either system test, calibrate or purge modes:
TEST PREFLOW or TEST CUTFLOW; CAL ZERO or
CAL SPAN; or automatic PURGE PREFLOW or PURGE
CUTFLOW for 20 seconds each.
Indicates GS-ERR (gas
system error). Refer to
Gas System Error List.
Indicates shield
cut flowrates
Indicates preflow
flowrates
Indicates plasma
cut flowrates
Potentiometer 6 and
associated LCD display
field only operate when
H35 is selected.
00%
00%
00%
00%
00%
00%
INLET GAS
REMOTE or LOCAL
INLET GAS
PS-ERR
GS-ERR
XXX PSI/BAR
XXX PSI/BAR
XXX PSI/BAR
TEST, CALIBRATE or PURGE MODE