30 amp, Operation pac186 mild steel o, Plasma / o – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual
Page 114: Shield 30 amp cutting
HD3070 with Automatic Gas Console
Instruction Manual
4-25
16
OPERATION
PAC186
Mild Steel
O
2
Plasma / O
2
& N
2
Shield
30 Amp Cutting
Material
Thickness
(GA)
(in)
(mm)
Arc
Voltage
(volts)
Torch
Standoff**
(in)
(mm)
Travel
Speed
(ipm)
(m/min)
Pierce
Delay
(dial)
(sec)
Initial
Piercing
Height
(in)
(mm)
24
0.024
0.6
5
75
15
5
46
–
103
0.030
0.8
200
5.08
0.040
1.0
0
0
22
0.030
0.8
5
75
15
5
46
–
108
0.030
0.8
170
4.32
0.040
1.0
0
0
20
0.036
0.9
5
75
15
5
46
–
110
0.040
1.0
140
3.56
0.060
1.5
0
0
18
0.048
1.3
5
75
15
5
46
–
112
0.040
1.0
110
2.80
0.060
1.5
0
0
16
0.060
1.5
5
75
15
5
46
–
115
0.040
1.0
80
2.03
0.060
1.5
0
0.1
14
0.075
1.9
5
75
15
5
46
–
118
0.040
1.0
60
1.52
0.060
1.5
0
0.1
12
0.105
2.7
5
75
15
5
46
–
121
0.060
1.5
50
1.27
0.080
2.0
.5
0.2
10
0.135
3.4
5
75
15
5
46
–
124
0.060
1.5
35
0.90
0.080
2.0
1
0.3
3⁄16
4.8
5
75
15
5
46
–
125
0.060
1.5
32
0.81
0.080
2.0
1.5
0.4
1⁄4
6.4
5
75
30
10
46
–
124
0.040
1.0
25
0.64
0.080
2.0
2
0.5
O
2
and N
2
gas inlet pressures must be between 105 - 135 psi (7.2 - 9.2 bar) for all material thickness.
#
Refer to LCD display Figure 4-3.
* Slightly increasing the test preflow O
2
and N
2
flowrates may increase piercing capability on the thicker materials listed above.
However, increasing the preflow flowrates too much may affect plasma starting reliability (misfiring).
** Torch standoff tolerances are ± 0.005 inch (± 0.125 mm). When using a THC, tolerances are ± 1 volt.
Counter clockwise (CCW) consumables are available for mirror image cutting. Refer to Section 6, Parts List.
If problems occur with the cutting process, and the flowrates are suspect, refer to Section 5, Maintenance, Gas System Back
Pressure Checks.
Shield
020671
Nozzle
020645
Electrode
120111
Retaining Cap
020633
Swirl Ring
020637
PAC186 Torch
120349
Shield Cap
020634/020687
Test Cut
Flowrates (%)
Shield
O
2
N
2
(3)
#
(4)
#
Plasma
O
2
(5)
#
(6)
#
Test Preflow*
Flowrates (%)
Preflow
O
2
N
2
(1)
#
(2)
#