Power supply cnc interface signals – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual
Page 247

a-2
HD3070 with Automatic Gas Console
Instruction Manual
16
APPENDIX A
Power Supply CNC Interface Signals
Power Supply Connector 1X1 Standard Interface
SIGNAL
PIN #
POL
DESCRIPTION
EXTERNAL
16
+
CNC MUST PROVIDE A CLOSED CKT TO ALLOW POWER
INTERLOCK
17
-
SUPPLY OPERATION. 12VDC, 80MA SINK REQUIRED.
INPUT
18
SHLD
1/50 ARC
33
+
SIGNAL PROPORTIONAL TO ARC VOLTS 4VDC OUTPUT WITH
VOLTAGE
28
-
200Vdc ARC. OUTPUT IS ISOLATED AND FLOATING.
OUTPUT
27
SHLD
INTERLOCKS
35
DRY
DRY CONTACT CLOSURE THAT IS CLOSED WHEN ALL
OK
30
DRY
POWER SUPPLY INTERLOCKS ARE SATISFIED.
OUTPUT
24
SHLD
TRANSFER
32
DRY
DRY CONTACT CLOSURE THAT IS CLOSED WHEN
OUTPUT
37
DRY
TRANSFER OCCURS. USED TO START PIERCE COMPLETE
26
SHLD
AND MACHINE MOTION TIMING.
POWER ON
29
+
CNC MUST PROVIDE A CLOSED CKT TO POWER UP
INPUT
34
-
THE POWER SUPPLY. CNC SHOULD MAINTAIN UNTIL
23
SHLD
INTERLOCKS OK OUTPUT BECOMES ACTIVE AND THEN OK
OUTPUT BECOMES ACTIVE AND REMOVE. IF INTERLOCKS
OK OUTPUT IS NOT RECEIVED IN A REASONABLE TIME (20
SEC) THEN CHECK INDIVIDUAL INTERLOCKS. 12V dc, 80mA
SINK REQUIRED.
PLASMA ON
15
DRY
CNC MUST INITIATE DRY CONTACT CLOSURE TO START
INPUT
9
DRY
AND OPERATE PLASMA.
14
SHLD
POWER OFF
8
+
CNC SHOULD PROVIDE A MOMENTARY CLOSED CIRCUIT
INPUT
4
-
TO POWER DOWN THE POWER SUPPLY. INPUT IS 12V dc
13
SHLD
AND REQUIRES SINKING 80mA.