Gas system -32 – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual
Page 157

5-32
HD3070 with Automatic Gas Console
Instruction Manual
16
MAINTENANCE
Gas System (GS-ERR)
Error Message
Error Code
Description
NO ERROR
0
LOW PLASMA GAS ERR
1
This error signal is issued if the plasma gas inlet pressure is
below 105 psig (7.2 bar).
LOW SHIELD GAS ERR
2
This error signal is issued if the shield gas inlet pressure is
below 105 psig (7.2 bar).
HIGH PLASMA GAS ERR
3
This error signal is issued if the plasma gas inlet pressure is
above 135 psig (9.3 bar).
HIGH SHIELD GAS ERR
4
This error signal is issued if the shield gas inlet pressure is
above 135 psig (9.3 bar).
MV1 ERR*
5
This error signal is issued when the MV1 motor valve does
not move when commanded. When this error occurs service
is required.
MV2 ERR*
6
This error signal is issued when the MV2 motor valve does
not move when commanded. \When this error occurs service
is required.
MV3 ERR*
7
This error signal is issued when the MV3 motor valve does
not move when commanded. When this error occurs service
is required.
MV4 ERR*
8
This error signal is issued when the MV4 motor valve does
not move when commanded. When this error occurs service
is required.
MV5 ERR*
9
This error signal is issued when the MV5 motor valve does
not move when commanded. When this error occurs service
is required.
MV6 ERR*
10
This error signal is issued when the MV6 motor valve does
not move when commanded. When this error occurs service
is required.
* The plasma system will have to be powered down and then restarted if any of the motor valve errors occur.