3-24
HD3070 with Automatic Gas Console
Instruction Manual
16
INSTALLATION
3X2
1X3
Automatic
Gas Console
Power Supply
RUN LIST
SIGNAL
PLUG 1X3
COLOR
PLUG 3X2
Gas Pressure
1
Red
1
or Contact Closure
2
Black
2
-
6
Shield
6
Gas System
3
White
3
or Contact Closure
4
Black
4
-
8
Shield
8
H35 & N
2
Plasma
10
Green
10
Contact Closure
11
Black
11
-
5
Shield
5
Test Operate Flow
14
Yellow
14
Contact Closure
15
Black
15
-
9
Shield
9
Test Preflow
12
Blue
12
Contact Closure
13
Black
13
-
7
Shield
7
O
2
Plasma 21
Brown
21
Contact Closure
22
Black
22
-
17
Shield
17
DC On Light
23
Red
23
-
24
White
24
-
19
Shield
19
Unassigned
20
Orange
20
Contact Closure
18
Black
18
-
16
Shield
16
Part Number
Length
023671
6 ft (1.8 m)
023927
10 ft (3 m)
023672
25 ft (7.6 m)
023928
50 ft 15 m)
023929
75 ft (23 m)
023930
100 ft (30.5 m)
023931
125 ft (38 m)
023932
150 ft (45.6 m)
8
Figure 3-18
Gas Console Control Cable