beautypg.com

Maintenance, Power supply relay board led status – run preflow – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 187

background image

5-62

HD3070 with Automatic Gas Console

Instruction Manual

16

MAINTENANCE

REC2

REC3

REC4

REC1

Auto Off
Relay LED
(D26)
P5.1

Output
Enable
LED (D20)

+12 VDC
LED (D6)

Surge Relay
CR4/
LED (D13)
P5.4

Figure 5-5

Power Supply Relay Board LED Status (3 of 4)

Blowout
Counter/
LED (D22)
P3.7

Torch
Ignition/
LED (D28)
P5.2

Main
Contactor
CON1/
LED (D12)
P5.5

1

8

High Voltage
Transformer
T1/
LED (D10)
P5.7

1 – Illuminates when error 7, 8, 9, or 10 occur.

2 – Remains off until any error.

3 – Illuminates when using 50 to 100 amps.

4 – Illuminates at start; goes out after arc transfer.

5 – Illuminates until arc transfer; goes out after arc transfer.

6 – Illuminates at arc transfer.

7 – Illuminates when gas is selected.

8 – Illuminates after arc transfer.

Power Supply

Relay Board LED Status – Run Preflow

Pilot Arc
Relay CR1/
LED (D11)
P5.6

3

2

4

5

7

7

6

LED On

LED Off

LED Momentarily On

O

2

Plasma/

LED (D18)
P6.7

Air Plasma/
LED (D16)
P6.5

Shield
Preflow/
LED (D7)
P6.2

H35 & N

2

Plasma/
LED (D17)
P6.6

7

Machine
Motion
LED D24)
P5.0

Message
Number/
LED (D15)
P6.4