MAINTENANCE
GS ERR=10
MOTOR VALVE 6 ERROR
Informs operator that motor valve 6 (MV6)
did not move when commanded.
To clear this error, power
down plasma system &
then reapply power.
Error corrected.
Replace MV6. Fig 6-13
No
No
Yes
Does MV6 error return
after reinitializing
plasma system ?
Does MV6 error return
after replacing MV6 &
reinitializing plasma
system ?
Yes
Does MV6 error return
after replacing control PCB
A1 & reinitializing plasma
system ?
Replace gas console
relay PCB A2.
Fig 6-12 (16)
Replace gas console
relay PCB A1.
Fig 6-12 (8)
Yes
Does MV6 error return
after replacing relay PCB A2
& reinitializing plasma
system ?
Contact Hypertherm
technical service.
Yes
No
No