Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual
Page 251

a-6
HD3070 with Automatic Gas Console
Instruction Manual
16
APPENDIX A
SIGNAL
PIN #
POL
DESCRIPTION
Gas Console Connector 3X4 CNC Interface (continued)
TEST
21
+
OPERATE
INPUT
TEST
22
+
PREFLOW
INPUT
REMOTE AIR
23
+
PLASMA
REMOTE
24
+
H35 & N
2
PLASMA
REMOTE O
2
25
+
PLASMA
COMMON
26
-
ERROR
27
OPEN
INPUT
COLL-
ECTOR
COMMON
28
-
THE CNC CAN ACTIVATE THIS INPUT TO FLOW CUTFLOW
GAS IN A TEST INPUT MODE. 12Vdc, 3mA
THE CNC CAN ACTIVATE THIS INPUT TO FLOW PREFLOW
GAS IN A TEST INPUT MODE. 12Vdc, 3mA
THE CNC CAN ACTIVATE THIS INPUT PLASMA GAS.
12Vdc, 3mA
THE CNC CAN ACTIVATE THIS INPUT PLASMA GAS.
12Vdc, 3mA
THE CNC CAN ACTIVATE THIS INPUT PLASMA GAS.
12Vdc, 3mA
SIGNAL COMMON.
SIGNAL COMMON.
THIS OUTPUT WILL BE ACTIVATED WHENEVER THERE IS
AN ERROR DISPLAYED ON THE LCD DISPLAY.
This manual is related to the following products: