Rcc 1x2 to thumbwheel switch wiring interface, Operation – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual
Page 271

HD3070 with Automatic Gas Console
Instruction Manual
e-3
16
APPENDIX E
RCC 1X2 to Thumbwheel Switch Wiring Interface
Refer to Figure e-2 for wiring interface data between receptacle 1X2 and the thumbwheel switch.
From RCC
1X2 Pin
Color
Thumbwheel
8
Yellow
#1-4
7
Orange
#1-2
6
Blue
#1-1
5
Brown
#2-8
4
Green
#2-4
3
Red
#2-2
2
White
#2-1
11
Black
#2-Common
12
Gray
#2-8
13
Violet
#3-1
RCC
Thumbwheel
Operation
Set the desired current using the thumbwheel switch on the RCC. Refer to Section 4, Operation, for the Cut Chart
data for current settings on the type and thickness of materials to be cut.
Figure e-2
RCC 1X2 to Thumbwheel Switch Wiring Interface