beautypg.com

Installation – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 55

background image

HD3070 with Automatic Gas Console

Instruction Manual

3-7

16

INSTALLATION

Table 3-1

Line Voltage Disconnect Box Fusing Requirements

Input

Rated Input Current @

Recommended

Voltage

15 kw Output

Slow-Blow Fuse Sizes

(VAC)

Phase/Hz

(amps)

(amps)

200

3/50-60

60

70

208

3/60

58

70

220

3/50-60

54

70

240

3/60

50

60

380

3/50-60

30

40

415

3/50-60

28

35

480

3/60

25

30

600

3/60

20

25