background image

5-22

HD3070 with Automatic Gas Console

Instruction Manual

16

MAINTENANCE

GAS SYSTEM LED not lit.

Install or
replace
microcomputer
Fig 6-12 (8)

Replace Gas
Console Control
PCB A1.
Fig 6-12 (8)

Replace or
connect cable.

Yes

Yes

Yes

Yes

No

No

No

No

Is Gas System Ok

LED D11 on Gas Console

Control PCB A1 lit. ?

Fig 5-8

Are

+5 VDC LED D3,

+12 VDC LED D22 &

-12 VDC LED D23,

on PCB A1 lit ?

Fig 5-8

Is Gas Console

microcomputer (042170)

defective or not installed

?

Fig 6-12

Is PS/gas console control

cable

defective or not connected ?

Fig 3-17 or 3-18