Gas console error messages -30, Power supply system -30 – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual
Page 155
5-30
HD3070 with Automatic Gas Console
Instruction Manual
16
MAINTENANCE
Gas Console Error Messages
The gas console displays error messages for both the plasma system and gas system (Figure 5-3.1). The plasma
system and gas system messages are listed below. Following these error messages, troubleshooting flow
diagrams are provided to help resolve the problems causing the error messages.
Figure 5-3.1
Automatic Gas Console LCD Display
Indicates PS-ERR (power supply system error).
Refer to Power Supply System Error List.
Indicates GS-ERR (gas system error).
Refer to Gas System Error List.
00%
00%
00%
00%
00%
00%
INLET GAS
REMOTE or LOCAL
INLET GAS
PS-ERR
GS-ERR
XXX PSI/BAR
XXX PSI/BAR
XXX PSI/BAR
TEST, CALIBRATE or PURGE MODE
Power Supply System (PS-ERR)
Error Message
Error Code
Description
NO ERROR
0
LOW COOLANT LEVEL**
1
Indicates that the coolant reservoir needs to have coolant
added.
INTERLOCK ERR**
2
This error is issued during operation when one of the
pressure or temperature switches connected to the power
distribution PCB is opened.
HOLD TIMEOUT ERR**
3
This error signal is issued if the HOLD INPUT signal was not
released within 10 seconds after the end of preflow.
NO PILOT TIMEOUT ERR**
4
This error signal is issued when the high frequency was
unable to ignite the pilot arc within 1 second.