HD3070 with Automatic Gas Console
Instruction Manual
3-9
16
INSTALLATION
220-Volt
415-Volt
380-Volt
Figure 3-3
220/380/415V Linkboard Configurations
Work Table Grounding
• The work table must be grounded properly to ensure personal safety, and to reduce the emission of radio-
frequency interference.
• See Appendix G for important grounding instructions.
Equipment Grounding
• The power supply, RHF console and gas console provide connections for protective earth (PE) grounding.
• See Appendix G for important grounding instructions.