For example, if you issue

1 5 7 0 SET-TAPS

then

tap 1 will output only the Z component (1);

tap 2 will output the Z and E components ( 1 + 4 = 5 );

tap 3 will output all three components ( 1 + 2 + 4 = 7 ); and

tap 4 will not output anything; and

To set triggered output streams, you should use the TRIGGERED

command described below.

5.4.3 SET CONFIG

Syntax: SET-CONFIG

Selects which streams and mux channels are to be output as

continuous data for each instrument. Two hexadecimal inputs are
required as shown below:

SET-CONFIG

Hex code to select DSP#1 'taps' {0000,0000} 0070,0000

Hex code to select mux channels {00ff} 0307

The 8 digit hex code for the 'taps' is structured as follows:

ABCD,EFGH

A = Tap0 on Instrument B

B = Tap0 on Instrument A
C = Tap1 on Instrument B

D = Tap1 on Instrument A
E = Tap2 on Instrument B

F = Tap2 on Instrument A
G = Tap3 on Instrument B

H = Tap3 on Instrument A

Each component within a tap on an instrument is given a binary value:

1 = Z
2 = N/S

4 = E/W
8 = X (the auxiliary input, present on 4 and 8 channel systems only)

60