1 system id – Guralp Systems CMG-CD24 User Manual
Page 26

CMG-CD24
•
the short-term and long-term average values for triggering (but
not which streams perform the trigger, or which are output by it)
(see section 3.1.3 on page 29)
•
the length of pre-trigger and post-trigger periods
•
calibration signal options
•
mass control functions
Some of these options can also be altered in the Configuration setup
window. For more information on the Control window, see section 3.2
on page 37.
If you need a more powerful interface to the CD24, you can also issue
commands to it directly using Scream!'s terminal mode. A terminal
window is opened by right-clicking on the digitiser's entry in the list
and selecting Terminal.... The digitiser will stop transmitting data
while you have a terminal window open but may still store it in Flash
memory (depending on the current transmission mode.)
The remaining sections of this chapter describe in detail the
configuration options available for the CD24. Many of these options
will also be available for other Güralp digitisers.
3.1.1 System ID
The System ID pane gives information about the digitiser and its
internal software and allows you to change GPS timing parameters.
System Identifier and Serial Number : The digitiser type is identified
by its system identifier and serial number. Every data and status block
26
Issue C