Gasboy 1000 Series FMS Startup Manual User Manual
Page 39

GASBOY Series 1000
9-2
03/07/03
Testing the Direct Connect Device
a. Turn on the direct connect device (e.g., data terminal).
b. Locate the ON-LINE switch on the terminal and place it in the ON position.
c. Press CTRL F or press RETURN. The system should respond: SIGN ON.
d.
Type
GASBOY and press RETURN. The system should respond with an asterisk (
*
).
NOTE: For security reasons, GASBOY does not print as you type it.
e.
Type
PD. The system prints the date, time, and transaction numbers followed by another
asterisk (
*
).
f.
Type
EX. The system prints EXIT. When connected to Port 1, the system goes into the
direct printout mode by printing the transaction header.
Testing the Modem
a. Turn on the modem/terminal device from which the call will originate.
b. Dial the Series 1000 site and establish a communication link with the system (See the
modem operator’s manual).
c. Press CTRL F or press RETURN. The system should respond: SIGN ON.
d.
Type
GASBOY and press RETURN. The system should respond with an asterisk (
*
).
NOTE: For security reasons, GASBOY does not print as you type it.
e.
Type
PD. The system prints the date, time, and transaction numbers followed by another
asterisk (
*
).
f.
Type
EX. The system prints EXIT.
g. Hang up the phone to terminate the communication link.
4.
Lower the hood onto the unit so that the four slots (two each side) on the hood side brackets
go over the pins on the base of the head assembly.
5.
Replace the four screws on the outside of the hood.
6.
Replace the two inside knobs.
7.
Close and lock the rear door of the hood assembly.