Gasboy 1000 Series FMS Startup Manual User Manual
Page 26

Jumper and Switch Settings
03/07/03
5-7
The TLS-250 Main PCB is located in the back of the TLS-250 box and accessed by opening the
right hinged cover. It contains a 5-position DIP switch bank, located at the upper left of the Main
PCB. These switches should be set as follows:
Switch Function
Status
1-3
Control Interboard Communication Rate
Always Closed
4
Parity: Closed, Odd; Open Even
Set to Open
5
Security Code option. Open, disable; Closed, enable.
Before setting this switch, see the Veeder Root
Communications Manual for additional details.
Set to user preference
Veeder-Root TLS-350 Tank Monitor Switch Settings
When the Series 1000 is connected to a Veeder Root TLS-350 tank level sensor, set the baud
rate jumper for 300 or 1200 baud. Setting the baud rate at 9600 is not recommended and may
result in a loss of data received from the TLS-350.
The TLS-350 communications parameters are configured via the TLS-350 front panel keypad.
Refer to the TLS-350 manuals for configuration options and how to change them.
The TLS-350 CPU board is located in the TLS-350 console printer compartment (lefthand door).
It contains a 4-position DIP switch bank, located in the lower righthand corner of the printer
compartment. These switches should be set as follows:
Switch
Function
Status
1
Front Panel Security Code Feature
Open, Disable; Closed, Enable
2
RS-232 Security Code Feature
Open, Disable; Closed, Enable
3 & 4
Not used
Fuel Point Reader Port and Baud Rate Jumpers
When a Fuel Point Reader (FPR) is connected to a FleetKey, it is connected to P3 (RS-422 Port
1). The K1 baud rate jumper for port 1 must be set for 1200 baud.