Config: misc: ( alarm mask: ( unit, Config: misc: ( alarm mask: ( uplink, Config: misc: ( alarm mask: ( downlink – Comtech EF Data CLO-10 User Manual
Page 69: Config: misc: æ alarm mask: æ unit, Config: misc: æ alarm mask: æ uplink, Config: misc: æ alarm mask: æ downlink

CLO-10 Link Optimizer
Revision 1
Front Panel Operation
MN/CLO-10.IOM
CONFIG: Misc: Æ Alarm Mask: Æ Unit
Unit Alarm Mask: ◄ ►
ERC ACQ_FAIL (ENT)
Select ERC or ACQ_FAIL using the ◄ ► arrow keys, then press
ENTER.
CONFIG: Misc: Æ Alarm Mask: Æ Unit Alarm Mask: Æ ERC
Unit Ext Ref Clk Alarm:
Active Masked (◄ ► ENT)
CONFIG: Misc: Æ Alarm Mask: Æ Unit Alarm Mask: Æ ACQ_FAIL
Unit Acq Failure Alarm:
Active Masked (◄ ► ENT)
For the Unit Alarm Mask ERC (Unit External Reference Clock) or ACQ_FAIL (Unit
Acquisition Failure) selections (as shown above), the user is prompted to select Active, whereas
the External Reference Clock alarm or Acquisition Failure alarm activates the fault relay, or
Mask, whereas the respective fault relay will not be activated.
Once Active or Masked is selected using the ◄ ► arrow keys, the user should then press
ENTER.
CONFIG: Misc: Æ Alarm Mask: Æ Uplink
Uplink AGC Alarm Mask:
Active Masked (◄ ► ENT)
The user is prompted to select Active, whereas the Uplink AGC alarm activates the fault relay, or
Mask, whereas the fault relay will not be activated.
Once Active or Masked is selected using the ◄ ► arrow keys, the user should then press
ENTER.
CONFIG: Misc: Æ Alarm Mask: Æ Downlink
Downlink AGC Alarm Mask:
Active Masked (◄ ► ENT)
The user is prompted to select Active, whereas the Downlink AGC alarm activates the fault relay,
or Mask, which deactivates the fault relay.
Once Active or Masked is selected using the ◄ ► arrow keys, the user should then press
ENTER.