7 iec line input (ac power) connector, 8 dc power connector – Comtech EF Data CLO-10 User Manual
Page 47

CLO-10 Link Optimizer
Revision 1
Rear Panel Connectors
MN/CLO-10.IOM
3–5
3.7
IEC Line Input (AC Power) Connector
The IEC line input connector contains the ON/OFF switch for the unit. It is also
fitted with two fuses, one each for line and neutral connections (or L1, L2, where
appropriate). These are contained within the body of the connector, behind a
small plastic flap.
A standard, detachable, non-locking, 3-prong power cord (IEC plug) supplies the
Alternating Current (AC) power to the CLO-10. Observe the following:
AC Power Specifications
Input Power
75W maximum, less than 65W typical
Input Voltage
100 - 240 volts AC, +6/-10% - autosensing
(total absolute max. range is 90 to 254 VAC)
Connector Type
IEC
Fuse Protection
• For 230 volt AC operation, use T2.5A, (slow-blow)
20mm fuses.
• For 115 volt AC operation, use T5.0A, (slow-blow)
20mm fuses.
3.8
DC Power Connector
A standard 3-screw terminal block supplies the Direct Current (DC)
power to the CLO-10. Observe the following:
IMPORTANT
For continued operator safety, always replace the fuses
with the correct type and rating.
DC Power Specifications
Input Power
200W maximum, less than 50W typical
Input Voltage
36 to 72 VDC; 6.25 amps
Connector Type
Terminal Block
Fuse Protection
3.15A Slow-blow
20mm type fuses
IMPORTANT
For continued operator safety, always replace the fuses with
the correct type and rating.