Front Panel Operation
MN/CLO-10.IOM
CONFIG: Remote Æ Serial Æ Baudrate
If Baudrate is selected:
Local M&C Bus Baud Rate:
19200 Baud (▲ ▼ ENT)
Edit the baud rate of the remote control bus, connected locally to the M&C computer. The value is
changed using the c d arrow keys. Values of 2400, 4800, 9600, 19200, 38400, and 57600 baud
are possible. Note that the asynchronous character format is FIXED at 8 data bits, 1 stop bit, no
parity (8-N-1).
Once the baud rate is edited, the user should press
ENTER
.
CONFIG: Remote Æ Ethernet
If Ethernet is selected:
Ethernet Config: Gateway
Address MAC (◄ ► ENT)
CONFIG: Remote Æ Ethernet Æ Gateway
If Gateway is selected:
Ethernet IP Gateway:
192.128.001.001 (ENT)
Edit the IP Gateway Address for the Ethernet M&C port for this unit by selecting the digit to be
edited, using the ◄ ► arrow keys. The value of the digit is then changed using the ▲ ▼ arrow
keys. The user should then press
ENTER
.
CONFIG: Remote Æ Ethernet Æ Address
If Address is selected:
Ether IP Address/Range:
192.168.001.001/24 (ENT)
Edit the IP Address and Range for the Ethernet M&C port for this unit by selecting the digit to be
edited, using the ◄ ► arrow keys. The value of the digit is then changed using the ▲ ▼ arrow keys.
The user should then press
ENTER
.
CONFIG: Remote Æ Ethernet Æ MAC
If MAC is selected, a read-only window displays , for the user’s reference, the factory program
MAC address for the Ethernet management interface: