Comtech EF Data CLO-10 User Manual
Page 106

CLO-10 Link Optimizer
Revision 1
Redundant System Operation
MN/CLO-10.IOM
Figure A-14 illustrates the operational status of the front panel LEDs for a Redundant Unit and
two Traffic Units (in this example, Traffic Units #1 and #2). In this example, Traffic Unit #2
experiences a REMOD fault and is being backed up in automatic operating mode:
• On the Redundant Unit:
o
The orange STORED EVENT LED indicator is on to alert the user that a fault
event has occurred that requires backup.
o
The green ONLINE LED is on to indicate that it is online, backing up the faulted
Traffic Unit #2.
• On Traffic Unit #2:
o
The green REMOD LED indicator is off because a fault has occurred.
o
The orange STORED EVENT LED indicator is on because the REMOD fault
has occurred.
o
The green ONLINE LED indicator is off because Traffic Unit #2 has been
backed up to the Redundant Unit.
When the system is in BACKUP mode, the Redundant Unit is online. In this event, the user may
not alter the bridge/backup state, and a message is shown instead of the menu:
MANUAL SELECT:
SWITCH IS IN AUTO MODE
Press CLR or ENT to return to the previous menu.
The system learns and retains the configuration of all of the active units in the set-up. This
configuration information is used to program the Redundant Unit to match the configuration of the
Traffic Unit being bridged.
A.6.3.5 Set the Redundant Unit Address via the Main Menu
IMPORTANT
Refer to
Sect. A.7 Daisy Chain Remote Addressing for detailed information
about address requirements to allow M&C of the Redundant Unit.
From the MAIN MENU, select the CONFIG: menu branch, then the Remote submenu (see
Sect. 6.4.1 in Chapter 6. FRONT PANEL OPERATION for full details).
MAIN MENU: Config Mon
Test Info Save/Load Util
CONFIG: Remote BW Uplink
Downlink Remod CnC Misc
A–22