Comtech EF Data CLO-10 User Manual
Page 128
CLO-10 Link Optimizer
Revision 1
Remote Control
MN/CLO-10.IOM
B-16
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to Controller)
Faults and Status
N/A
12 bytes
Query only.
Unit returns the current highest-prority fault and status
codes for the Unit (hardware), Uplink Traffic, Downlink
Traffic, and Remod in the form abcdef, where:
a=Unit Faults:
0=No Faults
1=Power Supply Fault, +5 volts
2=Power Supply Fault, +12 volts
3=Power Supply Fault, -12 volts
4=Reference PLL Fault
5=RU Configuration Error Fault
6= Loss Of CnC Lock Alarm
7=Ext Reference Clock Alarm
8=RU Traffic Unit Communication Timeout Alarm
9=RU Traffic Unit Error Alarm
a=RU Traffic Unit Invalid Configuration Alarm
the rest are reserved for future expansion
Items 5, 8 and 9 apply to Redundant Unit mode
b=Uplink Status:
0=Uplink OK
1=1
st
LO Synthesizer Lock Fault
2=2nd LO Synthesizer Lock Falut
3=Reference AGC Out Of Range Alarm
the rests are reserved for future expansion
c=Downlink Status:
0=Downlink OK
1=1
st
LO Synthesizer Lock Fault
2=2nd LO Synthesizer Lock Fault
3=AGC Out Of Range Alarm
the rests are reserved for future expansion
d=Remod status:
0= REMOD OK
1=1
st
LO Synthesizer Lock Fault
2=2nd LO Synthesizer Lock Fault
N/A FLT?
FLT=abcdef
(see description of
arguments)
e=Change in fault status
since last poll.
f=Change in unit
configuration since last
poll
(see description of
arguments)