Comtech EF Data CLO-10 User Manual
Page 121

CLO-10 Link Optimizer
Revision
1
Remote Control
MN/CLO-10.IOM
B.6.2
Remote Commands and Queries For the CLO-10 Link Optimizer
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command or
Response to
Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Uplink Frequency
UFQ=
9 bytes
Command or Query.
50 to 90/100 and 180 MHz (70/140 MHz units)
Resolution = 100 Hz
Example: UFQ=0070.0000
UFQ=
UFQ?
UFQ*
UFQ#
UFQ^
UFQ@
UFQ? UFQ=xxxx.xxxx
(see description of
arguments)
Downlink
Frequency
RFQ=
9 bytes
Command or Query.
50 to 90/100 and 180 MHz (70/140 MHz units)
Resolution = 100 Hz
Example: RFQ=0070.0000
RFQ=
RFQ?
RFQ*
RFQ#
RFQ^
RFQ@
RFQ? RFQ=xxxx.xxxx
(see description of
arguments)
Remod Frequency
TFQ=
9 bytes
Command or Query.
50 to 90 and 100 to 180 MHz (70/140 MHz units)
Resolution=100 Hz
Example: TFQ=0070.0000
TFQ=
TFQ?
TFQ*
TFQ#
TFQ^
TFQ@
TFQ? TFQ=xxxx.xxxx
(see description
arguments)
Remod Output
Enable
TXO
1 byte value.
0, 1
Command or Query.
1 = Enable the remodulation output
0 = Disable the remodulation output
Example: TXO=1 – Turn the remodulation output on
TXO=
TXO?
TXO*
TXO#
TXO^
TXO@
TXO TXO=x
Remod Output
Attenuation
TAT
1 byte value.
0 to 31.5 dB
Command or Query.
0 to 31.5 dB output attenuation in 0.5 dB steps
Example: TAT=25.5
TAT=
TAT?
TAT*
TAT#
TAT^
TAT@
TAT TAT=xx.x