B.6.3 commands and queries – Comtech EF Data CLO-10 User Manual
Page 127
CLO-10 Link Optimizer
Revision
1
Remote Control
MN/CLO-10.IOM
B.6.3
Commands and Queries
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to Controller)
Equipment ID
N/A 6
bytes
Query
only.
Unit returns information concerning the equipment
identification and the option field in the form: aaabcd,
where:
aaa=defines the model number (CLO-10 in this case)
aaa=010 for CLO-10
b=Defines Bandwidth Options:
1=2048 MHz
2=4096 MHz
3=8192 MHz
4=10000 MHz
c,d reserved
Example: EID=010200 means CLO-10 with 2048 Mhz
option, c,d reserved (c,d always set to 0,0)
N/A EID?
EID=aaabcd
(see description of
arguments)
Unit ID
N/A
4 bytes
Query only.
Unit returns information concerning the base unit
identification and the option field in the form: abcdefg,
where:
a=IF Mhz
1=70/140 MHz
b,c,d reserved
b,c,d always set to 0,0,0
N/A UID?
UID=abcd
(see description of
arguments)
B-15