Comtech EF Data CLO-10 User Manual
Page 119
CLO-10 Link Optimizer
Revision
1
Remote Control
MN/CLO-10.IOM
B.6.1
Switch Remote Commands and Queries for the CLO-10 Link Optimizer
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command or
Response to
Query
Description of Arguments
Response
to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Operating Mode
OPM=
1 byte
Command or Query.
‘x’ indicates the operating mode, where:
0 = manual mode
1 = auto mode
OPM=
OPM?
OPM*
OPM#
OPM^
OPM@
OPM? OPM=x
Bridged or Back-
up Unit Number
BBU=
3 bytes
Command or Query.
The bridge/back-up state, followed by the selected TU to be
acted on:
x is 0 = bridge
1 = backup (only possible when in manual mode)
yy is 01:12 for traffic unit number
BBU=
BBU?
BBU*
BBU#
BBU^
BBU@
BBU? BBU=xyy
Active Units
ACT=
12 bytes
Command or Query.
‘x’ indicates the active state of all 12 traffic units, where:
0 = de-activate traffic unit (except in back-up)
1 = activate traffic unit
ACT=
ACT?
ACT*
ACT#
ACT^
ACT@
ACT? ACT=xxxxxxxxxxxx
(see description of
arguments)
Active Unit Query
N/A
12 bytes
Query only.
‘x’ Indicates the state of all 12 traffic units, where:
0 = TU not Activated
1 = TU activated but not responding
2 = TU activated and responding
AUQ=
AUQ?
AUQ*
AUQ#
AUQ^
AUQ@
AUQ? AUQ=xxxxxxxxxxxx
(see description of
arguments)
Backup Holdoff
Time
BKH=
3 bytes
Command or Query.
The backup holdoff time is the delay when auto mode prepares
to backup a faulted traffic unit.
BKH=
BKH?
BKH *
BKH #
BKH ^
BKH@
BKH? BKH
=xxx
(see description of
arguments)
B-7