A.6.2 traffic unit redundancy configuration, A.6.3 redundant unit redundancy configuration – Comtech EF Data CLO-10 User Manual
Page 102
CLO-10 Link Optimizer
Revision 1
Redundant System Operation
MN/CLO-10.IOM
A.6.2 Traffic Unit Redundancy Configuration
Each Traffic Unit must have its Redundancy enabled and must be assigned a Traffic Unit Number that
corresponds to the number labeld on the High Speed Bus (HSB) cable connector. The Redundancy
screen is as shown:
Redundancy: En/Dis
Assign(#XX)
Select En/Dis or Assign (#XX) using the ◄ ► arrow keys. The user should then press ENTER.
If En/Dis is selected:
Redundancy En/Dis:
Enabled Disabled
This selection activates or deactivates redundancy operation for the unit. Select Enable or Disable
using the ◄ ► arrow keys. The user should then press ENTER.
If Assign (#XX) is selected:
Redundancy Assign:
CLO-10 #XX
The currently assigned number for the unit(#01 through #12) will be displayed. Assign the unit
number for placement within a 1:N redundancy system by using the ▲ ▼ arrow keys to select
#01 through #12.. The user should then press ENTER.
IMPORTANT
The unit’s assignment number must match that of the numbered DB-25
connector on the High Speed Bus cable (CEFD P/N CA/RB0014-XX-U2).
A.6.3 Redundant Unit Redundancy Configuration
When configuring a Redundant CLO-10, the Redundancy screen displays as follows:
Red: En/Dis Holdoffs
Active Auto(OFF) Manual
Select En/Dis, Holdoffs, Active, Auto, or Manual using the ◄ ► arrow keys. The user should
then press ENTER.
Note: Auto (OFF/ON) indicates the current staus of the Operating Mode (automatic or manual
operating mode).
A–18