Comtech EF Data CLO-10 User Manual
Page 125

CLO-10 Link Optimizer
Revision
1
Remote Control
MN/CLO-10.IOM
B-13
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command or
Response to
Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
IP Address
IPA=
18 bytes
numerical
Command or Query.
Used to set the IP Address and network prefix for the 10/100
BadeTX Ethernet management port, in the format:
xxx.xxx.xxx.xxx.yy, where:
yy is the network prefix (0 to 31)
Example: 010.006.030.001.24
IPA=
IPA?
IPA*
IPA#
IPA? IPA=xxx.xxx.xxx.xxx
.yy
(see description of
arguments)
Configuration
Save
CST=
1 byte
Command only.
Causes the CLO-10 to store the current unit configuration
(common functions and all four slots) in Configuration Memory
location defined by the 1-byte argument (0 to 9)
Example: CST=4 (store the current configuration in location 4)
CST=
CST?
CST*
CST#
CST^
N/A N/A
Configuration
Load
CLD=
1 byte
Command only.
Causes the CLO-10 to retrieve a previously stored unit
configuration (common functions and all four slots) in
Configuration Memory location defined by the
1-byte argument ( 0 to 9)
Example: CLD=4 (retrieve unit configuration from location 4)
CLD=
CLD?
CLD*
CLD#
CLD^
N/A N/A
RTC Date
DAY=
6 bytes
Command or Query.
A date in the form ddmmyy, where:
dd=day of the month (01 to 31)
mm=month (01 to 12)
yy=year (00 to 99)
Example: DAY=240457 (April 24, 2057)
DAY=
DAY?
DAY*
DAY#
DAY^
DAY? DAY=ddmmyy
(see
description of
arguments
RTC Time
TIM=
6 bytes
Command or Query.
A time in the form hhmmss, indicating the time from midnight,
where:
hh=hours (00 to 23)
mm=minutes (00 to 59
ss=seconds (00 to 59)
Example: TIM=231259 (23 hours, 12 minutes, 59 seconds)
TIM=
TIM?
TIME*
TIM#
TIM^
TIM? TIM=
hhmmss
(see
description and
arguments)