B.6.4 bulk commands and queries – Comtech EF Data CLO-10 User Manual
Page 131

CLO-10 Link Optimizer
Revision
1
Remote Control
MN/CLO-10.IOM
B-19
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to Controller)
Temperature of
the Base Unit
N/A 4
bytes
Query
only.
Unit returns the value of the internal base unit
temperature, in the form of sxxx (degrees C), where:
s=sign (+ or – character)
xxx=value
Example: ITP=+127
N/A ITP?
ITP=sxxx
(see description of
arguments)
B.6.4
Bulk Commands and Queries
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for Command
or Response
to Query
Description of arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to Controller)
Global
Configuration
MGC= 80
bytes,
with
numerical
entries, fixed
values and
delimiters
Command or Query.
The format is:
MGC=uuuu.uuuudddd.ddddrrrr.rrrrbbbbbfffggghhhemm
mmmmmmmmcaa.atxxxxxxxxxxxxxxxxxxxxxx, where:
MGC=
MGC?
MGC*
MGC#
MGC^
MGC?
MGC?n
MGC=uuuu.uuuudddd.ddd
drrrr.rrrrbbbbbfffggghhhem
mmmmmmmmmcaa.atxxxx
xxxxxxxxxxxxxxxxxx
Where n=0 to 9
Returns the MGC portion of
1 of 10 stored
configurations
(see description of
arguments)
uuuu.uuuu=Uplink Frequency
dddd.dddd=Downlink Frequency
rrrr.rrrr=Remod Frequency
bbbbb=Bandwidth Command
fff=CnC Frequency Offset
ggghhh=CnC Search Delay
e=External Reference Clock
mmmmmmmmmm=Unit Alarm Mask
c=Remod Output Control
aa.a=Remod Output Attenuation
t=Unit Test Mode (Read only)
xxxxxxxxxxx = reserved
xxxxxxxxxxx = reserved
same as UFQ
same as RFQ
same as TFQ
same as BWC
same as CCF
same as CSD
same as ERF
same as MSK
same as TXO
same as TAT
same as TST
reserved
reserved