Comtech EF Data CLO-10 User Manual
Page 124

CLO-10 Link Optimizer
Revision 1
Remote Control
MN/CLO-10.IOM
B-12
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command or
Response to
Query
Description of Arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Internal Reference
Oscillator Adjust
IRA= 5
bytes,
numeric
Command or Query.
Fine adjustment to the internal reference oscillator tuning
voltage, thereby, fine tuning the required internal reference
frequency.
Syntax: IRA=sxxxx
Where: s = sign (- or +)
Range: -2048 to +2047.
Example: IRA=+0192
IRA=
IRA?
IRA*
IRA#
IRA^
IRA? IRA=x
(see description of
arguments)
Test Mode
TST=
1 byte, value
of 0 through 4
Command or Query.
CLO-10 Test Mode, where:
0=Normal Mode (No Test)
1=Bypass
2=Uplink
3=TX CW
4=TX Alternating 1,0 Pattern
Example: TST=1 (Bypass)
TST=
TST?
TST*
TST#
TST^
TST@
TST? TST=x
(see description of
arguments)
Alarm Mask
MSK=
10 bytes
Command or Query.
Alarm mask condition, in form abcdefghij, where:
a=Unit Ext Ref Alarm (0=Unmasked, 1=Masked, X=
b=Unit Acq Failure Alarm (0=Unmasked, 1=Masked, X=
c=spare
d=Uplink AGC Alarm (0=Unmasked, 1=Masked, X=
e=Dnlink AGC Alarm (0=Unmasked, 1=Masked, X=
f,g,h,I,j=spare
Example: MSK=1001000011
MSK=
MSK?
MSK*
MSK#
MSK^
MSK? MSK=abcdefghij
(see description or
arguments)
Local/Remote
Status
LRS=
1 byte, value
of 0, 1
Command or Query.
Local/Remote status, where:
0=Local
1=Serial Remote
3=Ethernet Remote
Example: LRS=1 (Serial Remote)
LRS=
LRS?
LRS*
LRS#
LRS? LRS=x
(see description of
arguments)