A.5.4 Adding and Removing CLO-10s and/or Modules
► To add an additional CLO-10:
Step
Procedure
1
Attach all cables as outlined in A.3 CABLES AND CONNECTIONS.
2
Configure the modem and Optimizer as outlined in Chapter 4. MODEM AND
OPTIMIZER CONFIGURATION.
Figure A-12. Module Removal/Installation
► To remove a faulted Traffic Unit that is not being backed up:
Step
Procedure
1
De-activate the unit from the configuration.
2
Secure the module to the chassis using the (two) captive thumb screws.
3
Loosen the captive thumb screws securing the IOSM to the CLO-10 chassis. Do
not unplug the cable connections.
4
Remove the module from the chassis slot by sliding the module straight out until
it is clear of the chassis. See
NOTE: It is recommended that the unit being serviced is pushed a few inches
towards the front of the rack/cabinet in order to provide slack for the installed
HSB cable, thus easing removal of the still-cabled module.
A–15